Bachem Americas, Inc.
1271 Avenida Chelsea, Vista, California, United States
FEI 3000718309DUNS 080354773
FDA has 5 inspections on file for Bachem Americas, Inc. in Vista, California (FEI 3000718309), from 2010 to 2026. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 7 observations from the PDF; they are listed below. Five of the eight FOIA requests for this site have asked FDA for this inspection's records.
No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing and analysis, through Dec 31, 2026. Its registrant is Bachem Americas, Inc. (D-U-N-S 080354773).
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 5, 2010–2026
- 0 OAI · 3 VAI · 2 NAI
- Inspections with 483 observations shown
- 1 of 5
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 8 requests, latest Sep 22, 2026
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 7 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
API batch released without valid testing
QUALITY SYSTEM The Quality Unit failed to ensure that the drug substance was tested and released for distribution with appropriate laboratory determination of satisfactory conformance to final specifications prior to release. Specifically, (b)(4) API Batch #(b)(4) (Manufacturing Date: (b)(4) Jun 2024), was released without meeting all required release testing specifications. The identification of (b)(4) analysis, performed as part of the release testing and governed by controlled procedure Doc.# STM-3-00034, Rev. 09, Analysis of (b)(4) Composition of (b)(4) Using (b)(4) Analyzer, Effective Date: 23 Oct 2017, was found to have yielded unreliable results. Specifically, no system suitability was performed as required by the procedure, and therefore the system suitability acceptance criterion was not met. A re-injection of the chromatogram run was subsequently performed; however, the re-injection results were not used due to standard failure, resulting in the reporting of the original results without a completed system suitability. No deviation or investigation report was generated to document or address this failure. Furthermore, the analysis was reviewed and approved by QC personnel with the system suitability incorrectly documented as having been performed and the results recorded as within acceptance criteria, neither of which was accurate. The release testing results were subsequently included in the Certificate of Analysis (COA) and the batch was approved for release by the Quality Unit on 22 Jul 2024, despite the absence of a valid system suitability and without adequate scientific justification for the acceptance of the original results.
- Observation 2
Stability program not followed, inadequate oversight
The written stability testing program is not consistently followed, evidencing a lack of adequate Quality Unit oversight over the stability testing process and its associated controls, thereby compromising the integrity and reliability of stability data generated for drug substances and intermediates. Specifically, A. The quality unit failed to ensure that stability chambers are secured, and access controlled. During the facility walkthrough conducted on 13 May 2026, the stability chambers were observed to be locked; however, they are not situated in a secure location, nor is access to them restricted. The stability chambers are located in an open area of the laboratory (Room 114), in proximity to the receiving area. As a result, all personnel granted access to the laboratory, including contractors and maintenance personnel, have direct and unrestricted contact with the stability chambers, creating the potential for unauthorized manipulation of the chambers and, consequently, compromising the integrity of the stability program. Furthermore, on 15 May 2026, a glass window replacement operation was performed in the laboratory. This practice further demonstrates the lack of adequate access controls surrounding the stability chambers and presents a risk to the integrity of ongoing stability studies. B. The Quality Unit failed to ensure that stability samples were stored in a temperature-controlled or climate-controlled chamber for all studies and failed to follow controlled procedure Doc. SOP-3-00277, Rev. 29, Stability Program, Effective Date: 20 Oct 2025. Specifically, Section 9.3 of this procedure does not define ambient temperature storage conditions as distinct from room temperature storage conditions. It is the practice of the Quality Unit, as reflected in stability protocols # PROT-3-00554, (b)(4) (b)(4) and #(b)(4)-(b)(4) to store stability samples at ambient temperature in a locked cabinet within the QC Laboratory (Room 114 - Space Receiving Area). This area was found to be neither temperature-controlled nor subject to temperature monitoring or review. Furthermore, controlled procedure Doc. # SOP-3-00964, Rev. 09, (b)(4) Operation of (b)(4) Continuous Monitoring System, Effective Date: 27 Feb 2026, does not [illegible] Units (CTUs) to be monitored and reviewed. The following stability studies were found in the ambient uncontrolled temperature condition cabinet: Stability Protocol PROT-3-00554, (b)(4) (b)(4), Lot #(b)(4); Stability Protocol PROT-3-00554, (b)(4) (b)(4), Lot #(b)(4); Stability Protocol PROT-3-00554, (b)(4), Lot #(b)(4); Stability Protocol PROT-3-00710, (b)(4), Lot #(b)(4); Stability Protocol PROT-3-00395, (b)(4) (b)(4) Lot #(b)(4). C. Your Quality failed to always ensure that at least one batch per year is introduced to the stability program as required by your controlled procedure Doc. SOP-3-00277, Rev. 29, Stability Program, Effective date: 20 Oct 2025; specifically, under section 9.4.3 Annual Stability Program. This discrepancy was evident in that (b)(4) API, Batch #(b)(4) (Manufacturing date: (b)(4), Analytical Release date: 22 Jun 2024 and Commercially Release date: 6/13/2025), (b)(4) manufactured (b)(4) for FY2024, was not included in the stability program. In addition, this discrepancy was documented in Deviation Report # DEV-011412, opened on 23 May 2025 (QA approved 05 Jun 2025). The deviation report attributed the error to SOP-3-00721, Rev. 11 (the previous stability procedure), stating that it "does not clearly define the requirement for at least one annual batch for the stability program." However, this requirement is explicitly stated under Section 8.8.2 of the same procedure, contradicting the stated root cause. D. The Quality Unit failed to ensure that stability protocols are being followed, specifically with respect to the early removal of stability samples from climatic chambers and the timely completion of analytical testing consistent with established stability study intervals. These defic
Shortened here; the PDF has the full text.
Show observations 3 to 8
- Observation 3
Inadequate OOS investigations and root cause
Your Quality unit failed to perform thorough and adequate laboratory investigations, to obtain appropriate root cause, extend to other batches and proposed adequate corrective/preventive actions. The deficiencies are evidenced as follows: A. Your Quality Unit failed to conduct a thorough assessment and established adequate root cause and corrective and preventive action (CAPA) to avoid re-occurrence. For example, 1. Investigation Report # OOS-2024-022, for Out-of-Specification (OOS) results obtained for the (b)(4) API, Batch #(b)(4) disclosed OOS results for stability sample (b)(4) the unspecified related substance (b)(4) 1.83%; Limit: NMT (b)(4) 3.23% and (b)(4) and purity (96.8%; Limit: NLT (b)(4)). The root cause was attributed to laboratory error, specifically column degradation and/or sample preparation. It was determined that the analytical test would be repeated using a new column; however, all original system suitability acceptance criteria had been met, which does not support column degradation as a valid root cause. Furthermore, it is the firm's policy (b)(4) (b)(4) column, even for informational purposes, to demonstrate that column degradation was a contributing factor. The re-tested results were within specification, and the original OOS result was invalidated without adequate scientific justification. The root cause was not sufficiently challenged to ensure the validity of the conclusion. Additionally, no Corrective and Preventive Action (CAPA) was initiated to evaluate whether additional system suitability acceptance criteria are required to prevent recurrence. A similar deficiency was observed in Investigation Report # OOX-2025-004. 2. Investigation Report # OOS-2024-038, for Out-of-Specification (OOS) results obtained for the stability sample (b)(4) Batch #(b)(4) (b)(4) disclosed an OOS result for the (b)(4) Assay of (b)(4), with a result of 0.51 (b)(4) (b)(4) (Limit: NLT (b)(4) (b)(4)). The root cause was attributed to laboratory error due to the sample not being fully dissolved. This conclusion was demonstrated by evaluating the sample (b)(4) (b)(4) a practice not described or required by the analytical method, which raises concerns regarding the scientific validity of the root cause determination. It was subsequently determined to repeat the analytical test, ensuring the sample mixture was fully dissolved, and the original OOS result was invalidated. However, no corrective action or CAPA was initiated as a result of this investigation. Furthermore, a second investigation related to the same incident was opened approximately one month later, as documented in Investigation Report # OOS-2024-0196, raising additional concerns regarding the adequacy and completeness of the original investigation. 3. Investigation Report # OOS-2025-0177, for Out-of-Specification (OOS) results obtained for (b)(4) API, Batch #(b)(4) disclosed an OOS result for the Related Substance test, with an unspecified impurity result of 0.12% (Limit: NMT (b)(4)). The root cause was attributed to laboratory error due to contamination introduced during sample preparation. However, all completed checklists indicate that no abnormalities were observed during the sample preparation process, which directly contradicts the stated root cause of contamination. The sample was re-tested (b)(4) and found to be within specification; consequently, the original OOS result was invalidated and replaced with passing results without adequate scientific justification. Furthermore, the corrective action proposed was to provide training to the analyst; however, the investigation checklist describes the analyst as experienced and fully trained, with no testing method deviations identified. The proposed corrective action is therefore inconsistent with the findings of the investigation and does not adequately address the root cause or prevent recurrence. B. The Quality Unit failed to assess other batches during the investigation process that may have been impacted by
Shortened here; the PDF has the full text.
- Observation 5
Reserve samples improperly stored and controlled
Reserve samples are not always handled appropriately and/or retained is representative or consistent of finished drug substance or (b)(4) configuration being distributed and/or marketed. These deficiencies are evidence of inadequate Quality Unit oversight of this process. Specifically, A. The Quality Unit failed to ensure that retained samples are properly stored and to follow controlled procedure Doc. # SOP-3-00275, Rev. 13, Intermediates and API Retain Sample, Effective Date: 28 Jan 2025, specifically Section 8.6.4 regarding storage conditions. It is the practice of the Quality Unit to store retained samples designated for room temperature conditions in a locked cabinet within the QC Laboratory (Room 114, Space - Receiving Area), a location that is neither temperature-controlled nor temperature-monitored. Furthermore, controlled procedure Doc. # SOP-3-00964, Rev. 09, (b)(4) Operation of Continuous Monitoring System, Effective Date: 27 Feb 2026, does not identify Room 114 as a location requiring a critical deviation trigger for Controlled Temperature Units (CTUs) to be monitored and reviewed. Additionally, during the QC Laboratory walkthrough conducted on 15 May 2026, two bottles identified as retained samples were found stored in Refrigerator ID #(b)(4) which was neither locked nor access-controlled. The retained sample bottles were identified as follows: Retained Sample (Code (b)(4), Batch #(b)(4) (b)(4); Retained Sample - (b)(4) (Code (b)(4)), Batch #(b)(4). B. The Quality Unit failed to consistently ensure that retained samples are stored in container/closure systems equivalent to those used for the storage and distribution of the bulk (b)(4) and drug substance, as required by controlled procedure Doc. # SOP-3-00275, Rev. 13, Intermediates and API Retain Sample, Effective Date: 28 Jan 2025, specifically Section 8.6.2. The following deficiencies were observed: The retained sample was (b)(4), Batch #(b)(4) (b)(4) found stored in a clear glass container; however, the production batch record indicates the (b)(4) was packaged in a plastic container. Furthermore, the Sample Amount Report, generated was not uploaded to the LIMS system by the Material Management Team and not available or to be found. Therefore, it was possible to verify the amount received or the container/closure system used. (identified as (b)(4), Batch #(b)(4) (b)(4) (b)(4): The retained sample was stored in a plastic container; however, the Sample Amount Report dated 05 May 2026 indicates the container is described as a "clear glass container (b)(4)." This is inconsistent with the production batch record, which specifies that the (b)(4) is packaged in a plastic container/closure system. This discrepancy was not identified by Material Management or QC personnel. Furthermore, the Sample Amount Report for (b)(4) (b)(4) (b)(4), Batch #(b)(4) indicates that the container was sampled, weighed, and witnessed on 05 May 2026. However, as confirmed by the Production Manager, the container was actually sampled, weighed, and witnessed on 04 May 2026. The documentation was provided the following day by the Material Management Unit for signature, resulting in an inaccurate date recorded on the report. Therefore, the Quality Unit failed to ensure that processes and their associated documentation are executed and dated contemporaneously. C. The Quality Unit failed to ensure that the retained sample storage chamber (b)(4) (b)(4) is secured and access-controlled. During the facility tour conducted on 13 May 2026, it was observed that the retained sample storage chamber was locked; however, it is not located in a secure area with restricted access. Specifically, the retained sample chamber is situated in an open area of the laboratory, Room 114, near the microbiology laboratory area, where all personnel granted access to the laboratory including contractors and maintenance personnel have direct and unrestricted contact with the chamber. This lack of restricted access creates th
Shortened here; the PDF has the full text.
- Observation 6
Inadequate laboratory controls for reference standards
The established laboratory controls are inadequate, as they do not include scientifically sound and appropriate test procedures sufficient to ensure that they conform to appropriate standards of identity, strength, quality and purity. Specifically, A. Your Quality unit failed to ensure that all reference standards are properly labeled, and/or identified as per controlled procedure Doc. # SOP-3-00717, Rev. 10, Quality Control Reference Material Program, Effective date: 18 Feb 2025; specifically, under section 8.2.3, which state that reference standard labels are to contain: Assigned ID number, storage condition, lot number and applicable expiration date or re-test date. The following reference standards, used for the testing of raw materials, in-process samples, intermediates, and drug substance, were selected at (b)(4). It was observed that these standards were labeled only with an assigned ID number, with no storage conditions or expiration/retest date indicated: ID #(b)(4) [illegible], Lot (b)(4); ID #(b)(4), Lot (b)(4); ID #(b)(4), Lot (b)(4); ID #(b)(4), Lot (b)(4); ID #(b)(4) [illegible]. B. The quality unit failed to always use certified reference standards (RS) to ensure the accuracy and reliability of analytical testing. It is the quality unit's practice and policy to use uncertified reference standards for qualitative testing (e.g., identification tests, system suitability for HPLC normalization runs, IPC runs, etc.). However, as per controlled procedure Doc. # SOP-3-00717, Rev. 10, Quality Control Reference Material Program, Effective Date: 18 Feb 2025, specifically under Section 8.0, the procedure states that reference standards used for analysis include Compendial (i.e., USP, Ph. Eur., NIST, etc.), In-House RS (Qualitative or Quantitative RS), Non-Compendial, and Customer-Provided standards. Per this section, all types of reference standards are required to be certified, identified, and/or accompanied by their respective Certificate of Analysis (COA). This requirement is not exclusive to quantitative RS and applies equally to qualitative RS. In addition, under section 8.5.2 Qualitative In-House RS of this procedure states that (b)(4) unless it is required by material label. However, this practice does not ensure the Qualitative RS still meets its approved quality attributes over time and remains suitable for testing use and its regulatory purpose.
- Observation 7
Failure to prevent material mix-ups
FACILITIES AND EQUIPMENT SYSTEM Firm failed to establish and implement controls to prevent mix-ups of material from one dedicated area to another. Specifically, during walkthrough of the facility on 05/13/2026, we discovered a drum (Drum # (b)(4) of approved and released raw material (b)(4)) Lot #(b)(4) that was incorrectly located in the firm's outdoor Hazardous Waste collection area on the (b)(4) corner of Building. We observed the (b)(4) drum was exposed to the outdoor and in direct sunlight co-mingled with other drums and containers awaiting disposal. After informing Site QA Director and Site Leader of our discovery on 05/13/2026, we were informed in a meeting the next morning that the (b)(4) drum would be quarantined and eventually disposed of or destroyed. However, during a later walkthrough of the building facility on 05/14/2026 we observed production in-progress of Project (b)(4) on the (b)(4) floor of Room (b)(4) utilizing a drum of raw material (b)(4). The (b)(4) drum was later confirmed to be Drum # (b)(4) which we were informed was no longer in approved status and should not have been acceptable for use by production.
- Observation 8
Facility not maintained clean and controlled
Repeat Observation Your firm failed to properly maintain buildings and facilities used in the manufacture of (b)(4) and API in clean and controlled conditions. Specifically, A. Production room 303 (b)(4) doors opens directly the outdoor adjacent to the firm's hazardous waste collection area without adequate controls, presenting a significant risk of environmental contamination to the manufacturing area. B. The main (b)(4) door Room 303 exhibited visible gaps, light infiltration through the door frame, and accumulation of dust and debris on the adjacent interior floor, indicating a failure to maintain adequate environmental separation and cleanliness in manufacturing areas. C. At the time of inspection, Production Room 303 contained stored materials arranged in piles, which is not an acceptable practice for a designated production area. D. The flying insect light trap (#) in Production Room 303 was observed to be non-functional. E. Windows in production room 303 were covered with paper material to prevent dust ingress; however, the coverings were observed to be torn and separated from the window frame on multiple sides. F. During the May 13, 2026, walkthrough, hazardous waste, raw materials, and corrosive substances were observed stored outdoors without protection or proper segregation throughout the facility.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Eight requests to FDA under the Freedom of Information Act named this site, most recently on Sep 22, 2026.
Inspection ending May 20, 2026VAI
5 requests. In the inspection history above. FDA has posted its Form 483.
- Sep 22, 2026FDA-FOIA-2026-9206EIROpen
- Aug 21, 2026FDA-FOIA-2026-8122Form 483· 1 of 4 sitesRecords released
- Aug 11, 2026FDA-FOIA-2026-7728Form 483 + EIRRecords released
- Aug 10, 2026FDA-FOIA-2026-7641Form 483Records released
- Jul 15, 2026FDA-FOIA-2026-6728Form 483· 1 of 5 sitesRecords released
Inspection ending Mar 27, 2023VAI
1 request. In the inspection history above. FDA released records in answer to a request for its Form 483 + EIR on Jul 9, 2025. FDAgent holds no copy that FDA posted.
- Jul 3, 2025FDA-FOIA-2025-8253Form 483 + EIRRecords released
Inspection date not given
2 requests. None of FDA’s log entries for these requests say records were released.
- Jan 15, 2021FDA-FOIA-2021-358EIR· 1 of 2 sitesClosed
- Jan 14, 2021FDA-FOIA-2021-342Form 483· 1 of 2 sitesClosed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
FDA drug establishment registration
FDA registration search- Registered operations
- API manufacturing, analysis
- Registration runs through
- Dec 31, 2026
- Registrant
- Bachem Americas, Inc.D-U-N-S 080354773
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other FEIs recorded as Bachem Americas, Inc.
Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.
Bachem Americas, Inc.FEI 2024023Torrance, California, United States
Last inspected 2026-05-04VAI
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3000718309 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3000718309. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.