Alk-abello, Inc.
35 Channel Dr, Port Washington, New York, United States
FEI 2431784DUNS 809998847
FDA has 7 inspections on file for Alk-abello, Inc. in Port Washington, New York (FEI 2431784), from 2009 to 2023. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published one citation from this inspection, under 21 CFR Part 211, the manufacturing rules for finished drugs. It is listed below.
No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling, analysis, relabeling and repacking, through Dec 31, 2027. Its registrant is Alk-Abello, Inc. (D-U-N-S 809998847).
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 7, 2009–2023
- 0 OAI · 7 VAI · 0 NAI
- Inspections with 483 observations shown
- 3 of 7
- 1 posted 483 not matched to an inspection
- Form 483s posted by FDA
- ↗
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
7 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Vaccines and Allergenic Products1 citation published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Written record of investigation incomplete
Written records of investigations into unexplained discrepancies do not always include the conclusions and follow-up.
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Vaccines and Allergenic ProductsCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Vaccines and Allergenic Products2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Vaccines and Allergenic ProductsCitations not published
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Vaccines and Allergenic Products7 citations published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Deviations in special mix manufacturing
1. Product is not manufactured as described in the approved licensed. For example: A. Customers place orders for special mix lots, which are composed of [illegible] allergenic finished licensed products. The customer orders are not linked to the specific patients. Approximately [illegible] special mix lots can be manufactured per week. B. An appropriately identified reserve sample(s), representative of each lot or batch of product is not retained and/or stored under conditions consistent with product labeling and/or the same immediate container-closure system. Specifically, reserve samples are not maintained for special mixed lots. C. Each lot of special mix allergenic extract is not tested prior to release for conformance with all approved release specification for allergenic extracts. Special mix lots are only tested for conformance with sterility and visual inspection specification prior to final release. D. The sterility test method used for release testing of special mix allergenic extract products has not been validated for the intended purpose. The procedure for sterility testing as described SOP 117.05 (16143 version 03) version Sterility Testing For Sterile Preparation Manufactured in the Aseptic Processing Area (APA), has not been validated to show that the special mix allergenic extracts which can contain up to [illegible] different extracts are not bacteriostatic and/or fungistatic.
- Observation 2
Environmental monitoring and aseptic practices
2. Procedures designed to prevent microbiological contamination of sterile products are deficient. Specifically: A. Frequency of environmental monitoring performed on the Laminar Air Flow (LAF) Units in the Small Volume Production area (Room) where licensed (Made to Stock) and special mix products are aseptically manufactured is deficient. The LAF units in the aseptic filling area (Room) are only monitored [illegible]. B. During the observation of aseptic filling activities for Made to Stock Acremonium aqueous lot 1133949, and Fire Ant Lot 00001156868, both filling operators were observed to have facial skin exposed in grade [illegible] area (Room B).
Show observations 3 to 7
- Observation 3
No line clearance procedure for special mixes
3. The written procedure for special mix manufacturing, SOP 16150 3.0 The Manufacturing of Made to Order Special Mixes is silent with respect to procedures for line clearance between lots manufactured in laminar air flow units. The Small Volume Production area (Room) where special mixes are manufactured is equipped with [illegible] laminar flow hoods and a total of up to [illegible] lots of special mixes can be manufactured per day.
- Observation 4
No documented mixing requirement for specials
4. The manufacturing procedure for the use of [illegible] products processed into special mixes does not have a documented requirement for mixing of the products prior to custom special mixing. Filling instructions requires the be mixed for (b) (4) RPM for (®) (4). In addition, Made to Stock labeled vials requires the customer to “shake vial well before using”.
- Observation 5
Incomplete batch/process records
5. Batch manufacturing records and Process Simulation batch records for special mix allergenic extract and custom orders do not include complete information relating to production of each batch. Specifically, batch manufacturing records and process simulation records do not include complete information such as the laminar air flow units used in aseptic filling of the lot. In addition, the batch production records do not contain complete information for (b) (4) solutions used [illegible] for special mixes and custom orders.
- Observation 6
Failure to investigate distributed product
6. There is a failure to thoroughly investigation deficiencies for distributed product. Specifically, Lot 1E01299 failed stability at the [illegible] month test point for pH and precipitation (00S (b) (4). This Lot 1E01299 was used in allergenic extract dilutions. Final products with the diluent have been marketed and are still within expiry. The firm failed to evaluate all products in which the [illegible] was used as a diluent.
- Observation 7
Deficient lot numbering SOP
7. Current Lot numbering SOP WIN 11662 version 01 effective 10 June 2013 (b) (4) Process Order is deficient in that this SOP fails to clearly describe the lot numbering system utilized for all batches manufactured. SOP WIN 11662 only describes how to create a process work order.
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Vaccines and Allergenic ProductsCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Vaccines and Allergenic ProductsCitations not published
Regulations FDA cited here
The 2 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 7 inspections, with how many of them cited each.
- 21 CFR 211.113Control of microbiological contamination1 of 2
- 21 CFR 211.192Production record review1 of 2
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing, labeling, analysis, relabeling, repacking
- Registration runs through
- Dec 31, 2027
- Registrant
- Alk-Abello, Inc.D-U-N-S 809998847
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 2431784 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 2431784. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.