Spectrum Laboratory Products, Inc.
755, 769 And 777 Jersey Ave, New Brunswick, New Jersey, United States
FEI 2246824DUNS 962389607
Company: SPECTRUM LABORATORY PRODUCTS INC. · Linked by exact D-U-N-S match (075295246) in FDA registration data
FDA has 9 inspections on file for Spectrum Laboratory Products, Inc. in New Brunswick, New Jersey (FEI 2246824), from 2010 to 2025. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA has not published the citations from this inspection, and FDAgent holds no Form 483 that FDA posted for it. FDA posts only some 483s, so this does not show that none was issued. Three of the 11 FOIA requests for this site have asked FDA for this inspection's 483.
The most recent OAI inspection ended on Mar 24, 2023. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for relabeling and repacking, through Dec 31, 2027. Its registrant, SPECTRUM LABORATORY PRODUCTS INC. (D-U-N-S 075295246), has registered 1 other site.
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 9, 2010–2025
- 3 OAI · 4 VAI · 2 NAI
- Inspections with 483 observations shown
- 1 of 9
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 11 requests, latest FY2023
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
9 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 14 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate environmental controls
There is a failure to conduct repackaging operations under appropriate environmental conditions to avoid contamination and cross contamination. Specifica lly, the packing rooms within Buildings ____ that are repackaged, have not been [illegible] contamination. a. Within Building ____ the following were observed: i. There are no diagrams of a HVAC or air handling system for records of maintenance/qualification of the HVAC or air [handling]. ii. Packing Room 1 had a narrow ledge along the walls. The walls of Packing Room 1 were observed with yellow-colored streaks on the wall. Cleaning procedure PK-W-8.03 Cleaning and Sanitizing Microbiology Labs, Effective Date 1/26/2023 only requires cleaning on a (b)(•) basis. The Packaging Logbook (PK-CJ #3, 2/1/23 to 2/14/23) demonstrates that (b)(•) cleaning occurred on 2/1/23 and (b)(•) cleaning occurred on 2/6/23. Chemicals repackaged between 2/2/2023 and 2/16/2023 repackaged in these time frames include but are not limited to (b)(•) on 2/7/2023. iii. On 3/14/2023, Packing Rooms I which were documented in logbooks, were observed with (ti) residue on tables, biological safety cabinet, crevices of tables, on fume hoods, between the wall and floor molding, and [illegible]. b. The Packing Rooms within a building that were identified by your staff as an ISO 8 control environment: There are no procedures, qualifications, or monitoring performed to support this. Additionally, the following were observed on 2/8/2023: i. The Non-Hazardous Sampling Room had a (b)(•) covered with [illegible] and samples were (b)(•) ii. Packing room (b)(•) contained (b)(•) a larger table with a scale setting on it that appeared (b)(•). iii. Packing room (b)(•) contained spackle or caulk like substances in the fume hood and packaging area. There packaging operations were left uncovered. iv. Packing room (b)(•) had paint peeling on the wall, located above and in addition, the floor/drift was discolored yellow along the wall. v. Packing room (b)(•) contained a table with a scale positioned in front (b)(•). The table had peeling Magnehelic [gauge] and was settled below the (b)(•) area. vi. Packing room (b)(•) had bottles of reagents such as (b)(•) with no lot numbers or expirations. A (b)(•) bottle had an expiration [illegible].
- Observation 2
Cleaning validation lacking
Cleaning procedures are not validated. Specifically, a. Your firm has not validated cleaning procedures to evaluate the effectiveness and suitability of agents to disinfect hazardous APIs. There is no cleaning validation or verification protocol describing procedures, materials, acceptable cleaning levels, parameters, sampling, and analysis. i. The Quality Control Laboratory has been performing microbiological sampling and testing that was performed without documentation of any of the results. Procedure QAT-CLN02, Packing Room Cleaning Check/UV-Vis, 5/9/2013, is the only procedure provided for the cleaning validations. b. Your current cleaning procedure PK-W-8.03 entitled, Cleaning of Packing & Microbiology Labs, fails to include sufficient detail in the cleaning process to clean reliably, reproducibly, and consistently to reduce residuals on repackaged product to acceptable levels. c. Your current cleaning procedure document control number entitled, Packing Room Sanitation, Revision 11, Effective [illegible], Packing, Sampling, ISO Class 8 & Microbiology Labs, the procedure as indicated by your staff is Cleaning and Sanitizing Microbiology Labs, Effective Date 1/26/2023. This procedure [PK-W-8.03] removed cleaning the packaging room walls from after every packaging operation. Revision 11 to cleaning the walls on a (ti) basis is a change. There is no cleaning validation and no risk assessment to determine this change. Packaging operations in each room can vary on a (b)(•) basis. Multiple lots are repackaged within a room in both buildings.
Show observations 3 to 14
- Observation 3
Poor material traceability
There is a lack of defined areas or other control systems. Specifically, your firm does not have a control system to identify each material's status and location and nor does your firm have procedures for activities within the warehouse. a. The Oracle inventory system nor the batch router include (b)(A) (b)(A) building warehouse locations. On 2/8/2023, the following chemicals stored on shelves within the Warehouse however no (ll)(A) (li)(A) were entered into Oracle. i. Lot (b)(A) ii. Lot (b)(A) b. The Warehouse used to store (b)(A) did not have designated areas for materials not entered into Oracle, approved or quarantined. i. Areas of the warehouse are labeled as quarantined; however approved chemicals received within Oracle were observed on the shelves with quarantine stickers. Lot (b)(A) was stored on a shelf that is marked as Quarantine in Oracle. ii. Approved chemicals were observed stored in the receiving area. Lot (b)(A) were observed stored in the receiving area. Approved stickers dated 10/25/2022. iii. Non-API chemicals, (b)(A) Lot (b)(A) were observed in aisles of the warehouse with incoming receipt documentation still with the chemical containers. These chemicals were not entered into the Oracle system. iv. Oracle identified (b)(A) located (b)(A). c. There are materials that were documented as sampled in the Sampling Room. The materials were listed within Oracle inventory as per your staff and there are no distribution records. i. (b)(A) sampled on 9/8/2022; however router(s) do not include sampled. These lots could not be located within the warehouse.
- Observation 4
Inadequate OOS investigations
Written procedures are not established and followed for investigating critical deviations that may impact product quality. Investigations do not extend to determine the specific failure or deviation. Specifically, Out of Specification investigations do not contain supporting documents, statements, or interviews with laboratory technicians to support human error, corrective actions, or review for product impact. Examples include but are not limited to: • Out of Specification Investigation 2L-020 was initiated for (b)(•) exceeding the impurity limit of (l>)(l) ppm. The investigation does not contain supporting documents for a complaint report for the associated complaint, supporting laboratory notebook documentation, explanation of investigation steps, or the stock-lot check request. • Out of Specification Investigation 21-01~ was initiated for Assay with a result of (l>)(l) % (spec r:'.fo-Jo). This investigation [illegible] of all OOS investigation; however, the investigation was [illegible] investigation does not contain a statement or interview with the analyst with the cause being an improper weighing technique. • Out of Specification Investigation 2L-005 was initiated for (b)(•). The investigation was not further extended to determine impact on other methods. • Out of Specification Investigation 2K-021 was initiated for (b)(•) preparation of HPLC Buffers. The investigation was not (b)(•). (b)(•) was used for other test methods. This investigation was an OOS investigation; however, the investigation was not identified. • All Out of Specification investigations conclude without corrective actions, appropriate root cause analyses, or full product impact assessments.
- Observation 5
Test method suitability unverified
The suitability of all test methods used was not verified under actual conditions. Specifically, microbiological and analytical test methods have not been shown to ensure reliability of the test methods. a. Your firm states that microbiological testing is being performed; suitability studies have not been performed to demonstrate growth promotion of organisms from the USP is not being conducted. The documentation of Total Yeast and Mold testing is not being performed consistently. b. Endotoxin kit validation has not been performed for the endotoxin testing performed. The instructions included with the kit are not (l>)(4) and are placed (1>)(4) but increased for endotoxin testing. c. Method verification is not being performed for all analytical testing. Procedure QC-W-8.10, Laboratory-General Procedures, Revision 14, Effective 1/25/2023, section 5.1.3 defines criteria for method verification of compendial methods but these criteria are not being followed.
- Observation 6
Incomplete lab records
Laboratory control records do not include complete data with established specifications and standards, including examinations conducted. Specifically, the Microbiology and Analytical Laboratory notebooks do not include complete contemporaneous records of testing conducted. a. The Microbiology Laboratory notebooks for Endotoxin testing do not include sample preparation, observations of the control set, and (b)(•) b. The Microbiology Laboratory notebooks for Total Aerobic Plate Count testing are not contemporaneously documented. Test results include when the samples have begun incubation, when testing was performed, and who performed the reads are not consistently documented. i. Notebook QCCJI043 documents the testing for Total Aerobic (b)(•) Lot (b)(•) from 6/7/2022 - 6/10/2022; the testing reads 6/6/2022. ii. There are no test results for Total Aerobic Plate Count for QCCJI043 for (b)(•) Lot (b)(•) documented on the Certificate of Analysis. c. Analytical Laboratory notebooks do not include descriptions of GC analysis. The analytical package printed from the [illegible] does not include chromatograms.
- Observation 7
Inadequate specifications and testing
All specifications, sampling plans, and test procedures for raw materials, intermediates, APIs, and labels and packaging materials do not ensure identity and/or purity. Specifically, a. Sampling plans for identification testing of incoming lots per USP do not include all received containers. Examples include: i. outer cart (Lot #, Date: 01/11/2022 sampled 7 [illegible] ii. outer cart (Lot #, Date: 12/02/2021 sampled [illegible] b. The endotoxin specification for (b)(•) USP, (b)(•) manufacturer’s Certificate of Analysis. Your firm does not have documentation of this change in specification. i. The Spectrum Certificate of Analysis for (b)(•) states the endotoxin specification is EU/mL. The manufacturer's Certificate of Analysis reviewed by the Quality Control Laboratory for release states (b)(•) as having a result of (b)(•) EU/mL. If use exceeds (b)(•) ii. The Spectrum Certificate of Analysis for (b)(•) states the endotoxin specification is (b)(•). The manufacturer's Certificate of Analysis states the specification is MAX (b)(•) IU/g. The Spectrum Certificate of Analysis reports the results for Lot (b)(•) as (b)(•) IU/g. c. Incubation for Total Yeast and Mold Plate Counts for the Microbiology Laboratory is not performed within an incubator. Test samples are incubated in the Microbiological Laboratory. The temperature of the Microbiological Laboratory is not consistent and varies when product is being incubated for Total Yeast and Mold Counts. Temperatures within the Microbiology Laboratory varied and were as high as (b)(A) °C and as low as (li)(A) °C. i. (b)(•) was incubated for Total Yeast and Mold Counts. Temperatures within the Microbiology Laboratory varied (b)(A). d. There is a lack of evaluation of FTIR sample and standard spectra obtained during testing to evaluate the effects of poor sample preparation when performing FTIR. The peaks obtained are distorted, with intensities that appear saturated and lose resolution, making potential differences between sample and standard spectra difficult to ascertain.
- Observation 8
Stability studies not performed
Failure to conduct stability studies to justify assigned expiration dates when using different types of containers/closures than those used by the API manufacturer. Specifically, The Stability Program does not include stability testing for repackaged APIs. The Stability Program was established based on the original manufacturer's container/closure and the theoretical interactions and temperature within the repackaged container closure. There is no evaluation of the interaction or possible interaction between the specific container closure and the API.
- Observation 9
Deviations not properly investigated
There is a failure to make sure that all critical deviations are investigated and resolved. Specifically, a. Temperature excursions of refrigerators and freezers within Buildings ____ were not investigated. Procedure QC-W-6.01 entitled, Environmental Monitoring Facilities, states deviations are to be initiated to investigate temperature excursions of material storage areas. Since temperature excursions documented by your Dickson monitoring system were noted, no deviations were performed for any of these excursions. An example includes: i. The Walk-In Fridge within Building (b)(•) located on [illegible] had a high temperature excursion over 12 days, 7/22/2022-8/3/2022, with an average temperature of (b)(•). This refrigerator is 36-46°F (2.22 - 7.78°C). (b)(•) USP, Lot (b)(•) (storage requirement) and (b)(•) (storage requirement) were stored in this refrigerator and distributed to customers. b. Procedure QC-W-8.12, Rev. 5, Deviation System does not require risk assessments in the investigation. Deviations require a risk assessment to be documented when conducting risk assessments. c. Initiated deviations do not include supporting documentation. Deviations are canceled without documented justification. Examples include but are not limited to: i. Deviation Report 2022NJ005, initiated 3/1/2022 (still open), referenced events that occurred in 2021. There have been no corrective actions taken, no product impact assessments and no root cause analysis is provided. ii. Deviation Report 2022NJ015, initiated 12/2/2022, was created due to logbook errors of the same number. This deviation was canceled on 12/8/2022 with documentation placed with the deviation such as the master logbook pages to show distribution and individuals they were issued to. Logbooks QCCJI043 and QCCJI044 were first issued on 2/4/2022 to a Chemist and again on 6/29/2022, and QCCJI044 was issued on 2/25/2022 to a Chemist and then again on 8/1/2022 to a Laboratory Technician.
- Observation 10
Insufficient complaint investigations
There is a failure to conduct complaint investigations to determine product impact. Specifically, a. Complaints are received and categorized by your firm's Customer Care department located in [illegible]. Between 1/1/2021 to 2/22/2023, overall, your firm has received 5,679 complaints and the Quality Unit has only reviewed 58 complaints. There is no assurance all complaints for APIs are fully investigated. Examples include but are not limited to: i. On 11/10/2022, Complaint ID 165616 was received because a customer received (b)(•) of (l>)(•) USP. ii. On 11/30/2022, Complaint ID 174052 was received because it appeared product was shipped without proper shipping materials to ensure its temperature requirements. iii. On 2/8/2023, Complaint ID 204244 was received because the customer received (b)(A) (b)(•) instead of (b)(•). Your firm does not perform trend analysis for all API/drug complaints to implement appropriate corrective and preventive actions or conduct investigations. Many complaints include Broken/Missing Seal complaints all received (examples listed). b. Investigations into complaints are not thorough by failing to include all aspects of the complaint. i. Complaint PCS-8756 for (b)(•) USP was received for discoloration. The investigation focused entirely on clumping and did not evaluate the effects of discoloration on the product.
- Observation 11
Quality unit document failures
The Quality Unit does not review and approve all appropriate quality-related documents. Specifically, a. The Quality Unit does not review the entire router of distribution. Examples include but are not limited to: i. The router for (b)(•) USP, Lot (b)(•) includes voided completed pages with no notation within the router for the reason the packing operation that was carried out was not identified or corrected. For example, the packing operation was documented in the Room logbook, however it was documented (voided) in the router. b. The Quality Unit is not reviewing procedures to ensure they are accurate, whether procedures are created for all duties being performed, or retiring procedures when new ones are created. Examples include but are not limited to: i. Procedure PRO-W-8.05, Router, Effective 11/28/2022, states the Part A is to be completed by the Receiving Inspector. However, this is not performed by the Receiving department; Part A is printed by Production Personnel. ii. There are two cleaning procedures for the Packing Rooms under the same document control number PK-W-8.03: Packing Room Sanitation and Cleaning and Sanitizing Microbiology Labs. Both cleaning procedures do not have the same content and the most recent revisions conflict in terms of the cleaning frequency and cleaning agents. 1. The current revision for Packing Room Sanitation procedure [is] effective on 04/21/2021. 2. The current revision for Cleaning and Sanitizing Microbiology Labs is effective on 01/26/2023. However, revision 3 was effective on 9/13/2022. iii. There are no procedures describing microbiological testing methods. In addition, there are no procedures issuing notebooks for the microbiological laboratory and laboratory notebooks. c. The Quality Unit is not ensuring established procedures are followed. Examples include but are not limited to: i. Procedure QC-W-6.01, Environmental Monitoring Facilities, states that temperature monitoring data is to be reviewed on a (b)(•) basis and the Chief Chemist must initial a review demonstrating a review by the Chief Chemist. Records do not demonstrate a review by the Chief Chemist.
- Observation 12
Incomplete production records
Master Production Records do not include detailed production instructions. Specifically, routers do not include specific instructions on how to set up certain operations requiring it. In addition, the routers do not require the documentation of where samples were collected and what container was used for the sample collection for incoming receipt test and for the retain samples. a. The router for (b)(•) Lot (b)(•) states the starting quantity was [illegible]; the lot was sampled; however, no quantity was documented. The Spectrum Packing operation shipped the product to the customer despite both Oracle and the sampling logbook indicating that the lot was sampled.
- Observation 13
Router records not controlled
Batch Production and Control Records are not dated and signed. Specifically, there are no control procedures to ensure the routers in use are managed so that a router can be reprinted without identification on the document that ties it to a particular batch. There is no procedure to ensure completed routers are returned to any department for the filing and retention management. Routers can be reprinted without identification and distributed without clear responsibility assigned for filing and retention.
- Observation 14
Insufficient qualified personnel
There is not an adequate number of personnel qualified for the manufacture of APIs. Specifically, employees are carrying out duties without being provided adequate training. a. Employees in all departments are not trained on procedure QC-W-8.12, Rev. 5, Deviation System. Training records for employees in Packaging, Analytical Laboratory and Quality Assurance do not show completion of training for procedure QC-W-8.12, Rev. 5, Deviation System. b. Employees within the Analytical Laboratory and Quality Assurance are not trained on procedure QC-W-8.06, Out of Specification Laboratory Results. The Out of Specification Reports 2L-020 and 2M-001, and a Chemist completed the investigation section of Out of Specification Report 2J-026 and 2K-021 without any documentation of training. c. The Laboratory Technician within the Analytical Laboratory is reviewing data and performing microbiology testing with no training records.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
11 requests to FDA under the Freedom of Information Act named this site, most recently on FY2023.
Inspection ending Feb 19, 2025VAI
3 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Jul 8, 2025. FDAgent holds no copy that FDA posted.
- Oct 7, 2025FDA-FOIA-2025-11750Form 483Records released
- Jun 20, 2025FDA-FOIA-2025-7863Form 483· 1 of 10 sitesRecords released
- Apr 7, 2025FDA-FOIA-2025-3178Form 483· 1 of 5 sitesClosed
Inspection ending Mar 24, 2023OAI
3 requests. In the inspection history above. FDA has posted its Form 483.
- FY2023FDA-FOIA-2023-7059EIRClosed
- FY2023FDA-FOIA-2023-6963EIRWithdrawn
- FY2023FDA-FOIA-2023-4402Form 483Closed
Inspection ending Jul 14, 2021OAI
1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- FY2023FDA-FOIA-2023-6319Form 483Closed
Inspection ending Mar 12, 2019OAI
1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- May 3, 2021FDA-FOIA-2021-2841EIRDenied
Inspection date not given
3 requests. None of FDA’s log entries for these requests say records were released.
- FY2023FDA-FOIA-2023-4583Form 483Closed
- Nov 17, 2023FDA-FOIA-2023-10304Form 483· 1 of 2 sitesClosed
- Oct 17, 2023FDA-FOIA-2023-9125EIRClosed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
FDA drug establishment registration
FDA registration search- Registered operations
- Relabeling, repacking
- Registration runs through
- Dec 31, 2027
- Registrant
- SPECTRUM LABORATORY PRODUCTS INC.D-U-N-S 075295246
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names SPECTRUM LABORATORY PRODUCTS INC. (D-U-N-S 075295246) as the registrant for this site and the one other below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- SPECTRUM LABORATORY PRODUCTS INC. dba SPECTRUM CHEMICAL MFG. CORP.Gardena, California · FEI 20206329 inspections9latestMar 20, 2026VAI1 warning letter, Jun 4, 2019
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 2246824 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 2246824. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.