Central Alabama Veterans Health Care System
Alabama
FEI 1073935
FDA has 7 inspections on file for Central Alabama Veterans Health Care System in Alabama (FEI 1073935), from 2010 to 2026. The latest ended on ; FDA has not posted its classification yet.
FDA posted the Form 483 from that inspection. FDAgent read its 8 observations from the PDF; they are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- Inspections on file
- 7, 2010–2026
- 0 OAI · 0 VAI · 6 NAI
- Inspections with 483 observations shown
- 1 of 7
- Form 483s posted by FDA
- ↗
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
7 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- Not classified yetClassification not posted yetPosted 483 · 8 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate media fill practices
Failure to conduct media fills that closely simulate aseptic production operations under the worst-case, most-challenging, and stressful conditions. Specifically, A The media fill instructions in section 8(k) of SOP 119-19-12 require compounders use the (BD) (4) Validation” which contains (b) (4) and (B) (4). The (b) (4) during media fill does not closely simulate the (B) (4) consecutive drug product vials I saw (B) (4) during routine compounding of Remicade (infliximab) 750 mg/Sodium Chloride 0.9% 250 mL compounded sterile product (CSP), barcode 719803357553V28, on 04/10/26. B. Compounders use a new syringe for every vial and ampule during media fill. I watched a compounder using the same syringe to (b) (4) vials during routine compounding of Remicade (infliximab) 750 mg/Sodium Chloride 0.9% 250 mL CSP, barcode 719803357553V28, on 04/10/26 C. Your firm did not incubate all intact media fill units. A technician completed initial (D) (4) gowning competency (glove) qualification, media fill, and post-media fill surface sampling on about 10/30/25. Compounding personnel explained four of the 9 pre-compounding fingertip samples, the post-compounding fingertip samples, and the post-compounding surface sample were dropped and subsequently discarded on an unspecified date. The intact media fill unit and fingertip samples did not fall and were kept. Your firm sent the intact fingertip samples from 10/30/25 to the contract laboratory with all the samples and media bag collected during a repeat media fill on about 11/24/25. There is no justification for not sending the original media fill bag from 10/30/25 to the contract laboratory for incubation, [illegible] your firm sent the intact fingertip samples from that same day. The media fill bag was held in an inadequately calibrated (B) (4) incubator for an unknown period before it was discarded.
- Observation 2
Deficient smoke study procedures
Smoke studies were inadequately performed under dynamic conditions. Specifically, the most recent smoke study video available to review for your (D) (4) ISO 5 compounding aseptic (BD) (4) is dated 07/20/25. It did not contain enough information to verify airflow was suitable for aseptic compounding. A. There was not enough smoke to visualize airflow in the direct compounding area of the ISO 5 (B) (4). An approximately one-inch diameter stream of smoke was jetted directly onto the critical sites of the simulated CSP and (b) (4) from less than one foot away. B. There was no smoke introduced throughout the ISO 5 (B) (4) to determine if there was turbulent flow or dead spots. C. The two vials and one syringe used to simulate dynamic conditions during the smoke study were not representative of routine operations I observed, or the highest complexity operation used to produce CSPs. Items inside the ISO 5 (B) (4) during routine compounding of Remicade (infliximab) 750 mg/Sodium Chloride 0.9% 250 mL CSP, barcode 719803357553V28, on 04/10/26 included: a (B) (4) bin used to hold materials, about (b) (4) drug product vials, saline bag, syringe, needle, pair of sterile gloves, bottle of sterile (b) (4) hanging from an IV bar, and a pack of sterile wipes. D. The study did not introduce smoke or verify recovery time of unidirectional airflow inside the ISO 5 (B) (4) attached to the ISO 5 (B) (4). I watched the compounder move materials from the unclassified SCA into the ISO 5 (b) (4) and then immediately move the items into the ISO 5 (b) (4) during production of Remicade (infliximab) 750 mg/Sodium Chloride 0.9% 250 mL compounded sterile product (CSP), barcode 719803357553V28, on 04/10/26. E. The (b) (4) sliding door between the ISO 5 (b) (4) and ISO 5 (b) (4) was not evaluated during the smoke study for potential airflow disruption when compounders open it and (B) (4) into the (b) (4). F. The smoke study did not evaluate opening the (D) (4) outer door that connects to the unclassified SCA.
Show observations 3 to 8
- Observation 3
Use of non-sterile disinfectants
Use of non-sterile disinfecting agents in the ISO 5 area. Specifically. A. I watched a compounder wipe the ( ) (4) bin and all materials needed to produce Category 1 compounded sterile products (CSPs) with nonsterile (B) (4) in the unclassified SCA, move these items into the ISO 5 (b) (4) and then move the items into the ISO 5 (b) (4) without wiping them with a sterile disinfectant or sterile (BD) (4). Category 1 CSPs produced with these materials include: Tron Sucrose 200 mg/Sodium Chloride 0.9% 100 mL CSP, barcode 73513V15, on 04/09/26 B. I watched a compounder disinfect all surfaces in the ISO 5 and unclassified segregated compounding area (SCA) with nonsterile (B) (4) production and (B) (4) during the day per the approved procedure SOP 119-19-12. CSPs produced in the * include: Tron Sucrose 200 mg/Sodium Chloride 0.9% 100 mL CSP, barcode 73513V15, on 04/09/26 Remicade (infliximab) 750 mg/Sodium Chloride 0.9% 250 mL CSP, barcode 719803357553V28, on 04/10/26 Briumvi (ublituximab-xiiy) 450 mg/Sodium Chloride 0.9% 250 mL CSP, barcode 719803356510V10, on 04/10/26
- Observation 4
Supplies not re-disinfected at transitions
Lack of disinfection of supplies at each transition from areas of lower quality air to areas of higher quality air. Specifically, A The (B) (4) bin, drug product vials, unopened syringes and needles, pack of sterile wipes, pack of sterile gloves, and other materials wiped with (D) (4) remained in the unclassified SCA about (D) (4) before they were placed into the ISO 5 (b) (4) to the ISO 5 (b) (4) on the (b) (4) ISO 5. The compounder did not sanitize the items again before introducing them into the ISO 5 (b) (4) to produce one Remicade (infliximab) 750 mg/Sodium Chloride 0.9% 250 mL CSP, barcode 719803357553V28, on 04/10/26. B. The bottom of the (B) (4) bin containing items for the Remicade CSP directly contacted items when the compounder placed it on top of the bin containing sanitized material for a Briumvi CSP. The compounder did not sanitize the items again before introducing them into the ISO 5 (B) (4) to produce one Briumvi (ublituximab-xiiy) 450 mg/Sodium Chloride 0.9% 250 mL CSP, barcode 719803356510V10, on 04/10/26.
- Observation 5
Visible residue; inadequate cleaning
Failure to appropriately and regularly clean and disinfect or sterilize equipment located in the ISO 5 area. Specifically, there was visible residue on the walls and direct compounding area in the ISO 5 (B) (4) and ISO 5 (b) (4) on the (B) (4) during production of sterile products. CSPs produced in the (B) (4) include: Tron Sucrose 200 mg/Sodium Chloride 0.9% 100 mL CSP, barcode 73513V15, on 04/09/26 Remicade (infliximab) 750 mg/Sodium Chloride 0.9% 250 mL CSP, barcode 719803357553V28, on 04/10/26 Briumvi (ublituximab-xiiy) 450 mg/Sodium Chloride 0.9% 250 mL CSP, barcode 719803356510V10, on 04/10/26
- Observation 6
Poor environmental monitoring practices
Inadequate routine environmental monitoring in the ISO 5 area. Specifically, A Environmental monitoring (EM) and Media Fill records from the previous six months document your firm regularly kept media fill, gloved fingertip and thumb (GFT), and surface EM microbiology samples for multiple weeks, and in one instance more than one month, before sending them to the contract laboratory for incubation and testing. Personnel store the samples in a (B) (4) incubator that is not monitored or calibrated at that temperature range. There is inadequate justification to delay initiating incubation. The required incubation scheme for GFT and EM samples per SOP 119-19-12 starts with (B) (4) incubation before transfer to (B) (4). B. I observed one tray of (BD) (4) (b) (4) stored in its (BD) (4) tray exposed to the light in your inpatient pharmacy. The manufacturer Directions for Use instruct users to protect the (B) (4) from light. Compounders use these (b) (4) for GFT sampling and surface sampling the direct compounding area inside the ISO 5 (b) (4) and (b) (4) in the (D) (4) ISO 5.
- Observation 7
No operational pressure monitoring
No measurement of room pressure differentials was observed during operations to demonstrate proper airflow. Specifically, your firm does not adequately monitor differential pressure in the (B) (4) ISO 5. The standard configuration has Minihelic gauges for the (B) (4) and (b) (4) that are not connected to an audible alarm or alarm indicator light on the (b) (4) control panel. Additionally, personnel do not document differential pressure readings from either Minihelic gauge at least (B) (4) on days of compounding. CSPs I saw produced inside the (B) (4): Tron Sucrose 200 mg/Sodium Chloride 0.9% 100 mL CSP, barcode 73513V15, on 04/09/26 Remicade (infliximab) 750 mg/Sodium Chloride 0.9% 250 mL CSP, barcode 719803357553V28, on 04/10/26 Briumvi (ublituximab-xiiy) 450 mg/Sodium Chloride 0.9% 250 mL CSP, barcode 719803356510V10, on 04/10/26
- Observation 8
SCA contains hard-to-clean surfaces
Production areas have difficult to clean or contain porous, particle generating, or visibly dirty equipment or surfaces. Specifically, your unclassified segregated compounding area (SCA) established within the inpatient pharmacy contains surfaces that are not easily disinfected, impervious, free from damage, or are particle generating. The SCA does not have specific physical boundaries but is defined as a (b) (4) buffer zone around the (b) (4) ISO 5. The SCA contains a cracked drop ceiling tile which potentially allows the intrusion of air from the plenum, an exposed sprinkler head, an air supply vent, an approximate 1-inch hole in the drywall, textured mineral fiber drop ceiling tiles, small incubators, and (B) (4) oral solid dose counting machines. These surfaces could compromise the ISO 5 environment, particularly when the (b) (4) door is opened during cleaning, maintenance, or compounding activities. The SCA floor and ceiling are not included in the [illegible] or (D) (4) cleaning and disinfection logs.
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1073935 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1073935. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.