Sunland, Inc.
42593 Us Highway 70, Portales, New Mexico, United States
FEI 1000117188
FDA has one inspection on file for Sunland, Inc. in Portales, New Mexico (FEI 1000117188). It ended on and was classified NAI, no action indicated. FDA has also posted a Form 483 dated Jul 10, 2015 that FDAgent has not matched to an inspection on the Data Dashboard.
NAI means FDA found no objectionable conditions or practices, or found none that justified further action.
FDA posted the Form 483 from that inspection. FDAgent read its one observation from the PDF; it is listed below.
No warning letter, court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- NAI
- Inspections on file
- 1, in 2011
- Inspections with 483 observations shown
- 1 of 1
- 4 posted 483s not matched to an inspection
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- NAINo objectionable conditions that need follow-upVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices1 citation published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 2
Inadequate screening/protection against pests
Failure to provide adequate screening or other protection against pests. Specifically, a. On 3/23/11 - 3/24/11, the plastic strip door curtain located at the north production warehouse dock door was missing a strip. Raw product is stored approximately 20 feet from the plastic strip door curtain. b. On 3/23/11, three gaps were observed on the exit door on the southwest portion of the loading dock, and located approximately 6 feet from finished product. The first gap approximately 1/2 inch wide by 1 inch high, was observed under the southwest portion of the door. The second gap approximately 1/2 inch wide by 1 inch high, was observed under the northwest portion of the door. The third gap approximately 1/4 inch wide by 7 feet high was observed along the northern side of the door frame. c. On 3/24/11, two gaps were observed on the south dock door in the peanut butter cleaning room, and located approximately 12 feet from raw product. The first gap approximately 1/2 inch wide by 10 feet high, was observed along the north side of the dock door. The second gap approximately 1/4 inch wide by 3 feet high, was observed along the south side of the dock door.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1000117188 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1000117188. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.