21 CFR 640.81: Processing
FDA's inspection data lists 1 Form 483 citation of 21 CFR 640.81 at 1 facility, from September 2019 to September 25, 2019.
Counts: FDA Data Dashboard citations, last synced Nov 23, 2026, 04:25 UTC, and FDA's warning letters, last synced Nov 23, 2026, 04:17 UTC. Regulation text: eCFR. FDAgent is independent of FDA.
- Form 483 citations
- 1
- At 1 inspection
- Facilities cited
- 1
- Distinct FEIs
- Most recent citation
- Sep 25, 2019
- BAXALTA US INC.
- Warning letters
- 0
- State a violation of it
The regulation
The current text of 21 CFR 640.81 from the Electronic Code of Federal Regulations.
§ 640.81 Processing.
(a) Date of manufacture. The date of manufacture shall be the date of final sterile filtration of a uniform pool of bulk solution.
(b) Processing method. The processing method shall not affect the integrity of the product, and shall have been shown to yield consistently a product which is safe for intravenous injection.
(c) Microbial contamination. All processing steps shall be conducted in a manner to minimize the risk of contamination from microorganisms, pyrogens, or other impurities. Preservatives to inhibit growth of microorganisms shall not be used during processing.
(d) Storage of bulk fraction. Bulk concentrate to be held more than 1 week prior to further processing shall be stored in clearly identified closed vessels at a temperature of −5 °C or colder. Any other bulk form of the product, exclusive of the sterile bulk solution, to be held more than 1 week prior to further processing shall be stored in clearly identified closed vessels at a temperature of 5 °C or colder. Any bulk fraction to be held one week or less prior to further processing shall be stored in clearly identified closed vessels at a temperature of 5 °C or colder.
(e) Heat treatment. Heating of the final containers of Albumin (Human) shall begin within 24 hours after completion of filling. Heat treatment shall be conducted so that the solution is heated continuously for not less than 10, or more than 11 hours, at an attained temperature of 60±0.5 °C.
(f) Stabilizer. Either 0.08±0.016 millimole sodium caprylate, or 0.08±0.016 millimole sodium acetyltryptophanate and 0.08±0.016 millimole sodium caprylate per gram of protein shall be present as a stabilizer(s). Calculations of the stabilizer concentration may employ the labeled value for the protein concentration of the product as referred to in § 640.84(d).
(g) Incubation. All final containers of Albumin (Human) shall be incubated at 20 to 35 °C for at least 14 days following the heat treatment prescribed in paragraph (e) of this section. At the end of this incubation period, each final container shall be examined and all containers showing any indication of turbidity or microbial contamination shall not be issued. The contents of turbid final containers shall be examined microscopically and tested for sterility. If growth occurs, organisms shall be identified as to genus, and the material from such containers shall not be used for further manufacturing.
21 CFR Part 640: Additional Standards for Human Blood and Blood Products, Subpart HRead on eCFR
Citations by year
Form 483 citations of 21 CFR 640.81 by the year the inspection ended. FDA's citation data starts with inspections ending in October 2008, and the current year runs to the latest sync, so both are partial years (lighter bars).
Peak: 1 in 2019
| Year | Form 483 citations |
|---|---|
| 2019 | 1 |
How FDA words this citation
FDA's short descriptions and citation text on these 1 citation, most used first. These are FDA's standard summaries in its citation data, not the text of any one Form 483.
Short descriptions
- Microbial contamination1 citations
Citation text
- “All processing steps were not conducted in a manner to minimize the risk of contamination.”1 citations
Facilities cited most recently
The latest inspections where FDA cited 21 CFR 640.81, by inspection end date, with FDA's short description. Each links to the facility's FDA record on FDAgent.
Often cited at the same inspection
Of the 1 inspection where FDA cited 21 CFR 640.81, the share where it also cited each of these sections.
- 21 CFR 807.22Times for establishment registration and device listing1 (100%)
Ask FDAgent about 21 CFR 640.81
FDAgent reads FDA's Form 483 citations, observations and warning letters and answers in plain English, with links to the records.
Related
About this data
- Citation counts come from FDA's Data Dashboard, which lists the regulation behind each Form 483 observation for inspections since October 2008.
- Observation excerpts come from Form 483 PDFs in FDA's electronic reading room, tied to this section only by exact wording as described above.
- A warning letter counts for this section when one of its numbered violation sentences cites 21 CFR 640.81; FDAgent quotes that sentence exactly.
- FDAgent rebuilds this page every week from FDA's public data and is independent of FDA.