21 CFR 1271.10: Are my HCT/P's regulated solely under section 361 of the PHS Act and the regulations in this part, and if so what must I do?
FDA's inspection data lists no Form 483 citations of 21 CFR 1271.10. 4 warning letters state a violation of it.
Counts: FDA Data Dashboard citations, last synced Nov 23, 2026, 04:25 UTC, and FDA's warning letters, last synced Nov 23, 2026, 04:17 UTC. Regulation text: eCFR. FDAgent is independent of FDA.
- Form 483 citations
- 0
- At 0 inspections
- Facilities cited
- 0
- Distinct FEIs
- Most recent citation
- —
- None
- Warning letters
- 4
- State a violation of it
The regulation
The current text of 21 CFR 1271.10 from the Electronic Code of Federal Regulations.
§ 1271.10 Are my HCT/P's regulated solely under section 361 of the PHS Act and the regulations in this part, and if so what must I do?
(a) An HCT/P is regulated solely under section 361 of the PHS Act and the regulations in this part if it meets all of the following criteria:
(1) The HCT/P is minimally manipulated;
(2) The HCT/P is intended for homologous use only, as reflected by the labeling, advertising, or other indications of the manufacturer's objective intent;
(3) The manufacture of the HCT/P does not involve the combination of the cells or tissues with another article, except for water, crystalloids, or a sterilizing, preserving, or storage agent, provided that the addition of water, crystalloids, or the sterilizing, preserving, or storage agent does not raise new clinical safety concerns with respect to the HCT/P; and
(4) Either:
(i) The HCT/P does not have a systemic effect and is not dependent upon the metabolic activity of living cells for its primary function; or
(ii) The HCT/P has a systemic effect or is dependent upon the metabolic activity of living cells for its primary function, and:
(a) Is for autologous use;
(b) Is for allogeneic use in a first-degree or second-degree blood relative; or
(c) Is for reproductive use.
(b) If you are a domestic or foreign establishment that manufactures an HCT/P described in paragraph (a) of this section:
(1) You must register with FDA;
(2) You must submit to FDA a list of each HCT/P manufactured; and
(3) You must comply with the other requirements contained in this part.
21 CFR Part 1271: Human Cells, Tissues, and Cellular and Tissue-Based Products, Subpart ARead on eCFR
Warning letters stating a violation of 21 CFR 1271.10
4 warning letters FDA posted state a violation of this section in a numbered violation sentence. The most recent are below, each linking to FDAgent's page for the letter.
“Your umbilical cord derived product fails to meet the criterion that the HCT/Ps be “intended for homologous use only.” Homologous use means that the “labeling, advertising, or other indications of the manufacturer’s objective intent” demonstrate that the HCT/P is intended to perform “the same basic function or functions in the recipient as in the donor” (21 CFR 1271.3(c) and 1271.10(a)(2)).”
- Calibrate IV HydrationIssued 2026-10-13
“Your embryonic stem cell and placenta derived products fail to meet the criterion that the HCT/Ps be “intended for homologous use only.” Homologous use means that the “labeling, advertising, or other indications of the manufacturer’s objective intent” demonstrate that the HCT/P is intended to perform “the same basic function or functions in the recipient as in the donor” (21 CFR 1271.3(c) and 1271.10(a)(2)).”
- Beaute BountyIssued 2026-09-25
“Your product fails to meet the criterion in 21 CFR 1271.10(a)(2) that the HCT/Ps be “intended for homologous use only.” Homologous use means that the “labeling, advertising, or other indications of the manufacturer’s objective intent” demonstrate that the HCT/P is intended to perform “the same basic function or functions in the recipient as in the donor” (21 CFR 1271.3(c) and 1271.10(a)(2)).”
- NexCell Scientific IncIssued 2026-09-11
“Your umbilical cord blood derived stem cell product fails to meet the criterion that the HCT/Ps be “intended for homologous use only.” Homologous use means that the “labeling, advertising, or other indications of the manufacturer’s objective intent” demonstrate that the HCT/P is intended to perform “the same basic function or functions in the recipient as in the donor” (21 CFR 1271.3(c) and 1271.10(a)(2)).”
- Blue Horizon International, LLCIssued 2026-05-26
Ask FDAgent about 21 CFR 1271.10
FDAgent reads FDA's Form 483 citations, observations and warning letters and answers in plain English, with links to the records.
Related
About this data
- Citation counts come from FDA's Data Dashboard, which lists the regulation behind each Form 483 observation for inspections since October 2008.
- Observation excerpts come from Form 483 PDFs in FDA's electronic reading room, tied to this section only by exact wording as described above.
- A warning letter counts for this section when one of its numbered violation sentences cites 21 CFR 1271.10; FDAgent quotes that sentence exactly.
- FDAgent rebuilds this page every week from FDA's public data and is independent of FDA.