21 CFR 113.60: Containers
FDA's inspection data lists 2 Form 483 citations of 21 CFR 113.60 at 2 facilities, from January 2023 to June 20, 2025.
Counts: FDA Data Dashboard citations, last synced Nov 23, 2026, 04:25 UTC, and FDA's warning letters, last synced Nov 23, 2026, 04:17 UTC. Regulation text: eCFR. FDAgent is independent of FDA.
- Form 483 citations
- 2
- At 2 inspections
- Facilities cited
- 2
- Distinct FEIs
- Most recent citation
- Jun 20, 2025
- Etablissements Clement Faugier Marrons Glaces de l'Ardeche, S.A.
- Warning letters
- 0
- State a violation of it
The regulation
The current text of 21 CFR 113.60 from the Electronic Code of Federal Regulations.
§ 113.60 Containers.
(a) Closures. Regular observations shall be maintained during production runs for gross closure defects. Any such defects shall be recorded and corrective action taken and recorded. At intervals of sufficient frequency to ensure proper closure, the operator, closure supervisor, or other qualified container closure inspection person shall visually examine either the top seam of a can randomly selected from each seaming head or the closure of any other type of container being used and shall record the observations made. For double-seam cans, each can should be examined for cutover or sharpness, skidding or deadheading, false seam, droop at the crossover or lap, and condition of inside of countersink wall for evidence of broken chuck. Such measurements and recordings should be made at intervals not to exceed 30 minutes. Additional visual closure inspections shall be made immediately following a jam in a closing machine, after closing machine adjustment, or after startup of a machine following a prolonged shutdown. All pertinent observations shall be recorded. When irregularities are found, the corrective action shall be recorded.
(1) Teardown examinations for double-seam cans shall be performed by a qualified individual and the results therefrom shall be recorded at intervals of sufficient frequency on enough containers from each seaming station to ensure maintenance of seam integrity. Such examinations and recordings should be made at intervals not to exceed 4 hours. The results of the teardown examinations shall be recorded and the corrective action taken, if any, shall be noted.
(i) Required and optional can seam measurements:
(a) Micrometer measurement system:
Required | Optional
Cover hook | Overlap (by calculation).
Body hook | Countersink.
Width (length, height) |
Tightness (observation for wrinkle) |
Thickness |
(b) Seam scope or projector:
Required | Optional
Body hook | Width (length, height).
Overlap | Cover hook.
Tightness (observation for wrinkle) | Countersink.
Thickness by micrometer |
(c) Can double seam terminology:
(1) “Crossover”: The portion of a double seam at the lap.
(2) “Cutover”: A fracture, sharp bend, or break in the metal at the top of the inside portion of the double seam.
(3) “Deadhead”: A seam which is incomplete due to chuck spinning in the countersink.
(4) “Droop”: Smooth projection of double seam below bottom of normal seam.
(5) “False seam”: A small seam breakdown where the cover hook and the body hook are not overlapped.
(6) “Lap”: Two thicknesses of material bonded together.
(ii) Two measurements at different locations, excluding the side seam, shall be made for each double seam characteristic if a seam scope or seam projector is used. When a micrometer is used, three measurements shall be made at points approximately 120° apart, excluding the side seam.
(iii) Overlap length can be calculated by the following formula:
The theoretical overlap length = CH + BH + T − W, where
CH = cover hook
BH = body hook
T = cover thickness, and
W = seam width (height, length)
(2) For glass containers with vacuum closures, capper efficiency must be checked by a measurement of the cold water vacuum. This shall be done before actual filling operations, and the results shall be recorded.
(3) For closures other than double seams and glass containers, appropriate detailed inspections and tests shall be conducted by qualified personnel at intervals of sufficient frequency to ensure proper closing machine performance and consistently reliable hermetic seal production. Records of such tests shall be maintained.
(b) Cooling water. Container cooling water shall be chlorinated or otherwise sanitized as necessary for cooling canals and for recirculated water supplies. There should be a measurable residual of the sanitizer employed at the water discharge point of the container cooler.
(c) Coding. Each hermetically sealed container of low-acid processed food shall be marked with an identifying code that shall be permanently visible to the naked eye. When the container does not permit the code to be embossed or inked, the label may be legibly perforated or otherwise marked, if the label is securely affixed to the product container. The required identification shall identify in code the establishment where packed, the product contained therein, the year packed, the day packed, and the period during which packed. The packing period code shall be changed with sufficient frequency to enable ready identification of lots during their sale and distribution. Codes may be changed on the basis of one of the following: intervals of 4 to 5 hours; personnel shift changes; or batches, as long as the containers that constitute the batch do not extend over a period of more than one personnel shift.
(d) Postprocess handling. Container handling equipment used in handling filled containers shall be designed, constructed, and operated to preserve the can seam or other container closure integrity. Container handling equipment, including automated and non-automated equipment, shall be checked with sufficient frequency and repaired or replaced as necessary to prevent damage to containers and container closures. When cans are handled on belt conveyors, the conveyors should be constructed to minimize contact by the belt with the double seam, i.e., cans should not be rolled on the double seam. All worn and frayed belting, can retarders, cushions, etc. should be replaced with new nonporous material. All tracks and belts that come into contact with the can seams should be thoroughly scrubbed and sanitized at intervals of sufficient frequency to avoid product contamination.
21 CFR Part 113: Thermally Processed Low-Acid Foods Packaged in Hermetically Sealed Containers, Subpart DRead on eCFR
Citations by year
Form 483 citations of 21 CFR 113.60 by the year the inspection ended. FDA's citation data starts with inspections ending in October 2008, and the current year runs to the latest sync, so both are partial years (lighter bars).
Peak: 1 in 2023
| Year | Form 483 citations |
|---|---|
| 2023 | 1 |
| 2025 | 1 |
How FDA words this citation
FDA's short descriptions and citation text on these 2 citations, most used first. These are FDA's standard summaries in its citation data, not the text of any one Form 483.
Short descriptions
- Coding - required elements1 citations
- Frequency: visual closure examinations, record1 citations
Citation text
- “A qualified container closure inspection person did not record the observations made of the top seam of a can randomly selected from each seaming head and the container closures at intervals of sufficient frequency to ensure proper closure.”1 citations
- “The identification code for hermetically sealed containers did not identify in code the establishment where packed, year packed and day packed.”1 citations
Facilities cited most recently
The latest inspections where FDA cited 21 CFR 113.60, by inspection end date, with FDA's short description. Each links to the facility's FDA record on FDAgent.
- Etablissements Clement Faugier Marrons Glaces de l'Ardeche, S.A.2025-06-20 · FEI 3004269631Coding - required elements
Often cited at the same inspection
Of the 2 inspections where FDA cited 21 CFR 113.60, the share where it also cited each of these sections.
- 21 CFR 108.35Thermal processing of low-acid foods packaged in hermetically sealed containers1 (50%)
Ask FDAgent about 21 CFR 113.60
FDAgent reads FDA's Form 483 citations, observations and warning letters and answers in plain English, with links to the records.
Related
About this data
- Citation counts come from FDA's Data Dashboard, which lists the regulation behind each Form 483 observation for inspections since October 2008.
- Observation excerpts come from Form 483 PDFs in FDA's electronic reading room, tied to this section only by exact wording as described above.
- A warning letter counts for this section when one of its numbered violation sentences cites 21 CFR 113.60; FDAgent quotes that sentence exactly.
- FDAgent rebuilds this page every week from FDA's public data and is independent of FDA.