21 CFR 113.100: Processing and production records
FDA's inspection data lists 3 Form 483 citations of 21 CFR 113.100 at 3 facilities, from June 2023 to September 3, 2026.
Counts: FDA Data Dashboard citations, last synced Nov 23, 2026, 04:25 UTC, and FDA's warning letters, last synced Nov 23, 2026, 04:17 UTC. Regulation text: eCFR. FDAgent is independent of FDA.
- Form 483 citations
- 3
- At 3 inspections
- Facilities cited
- 3
- Distinct FEIs
- Most recent citation
- Sep 3, 2026
- Premier Canning Industry Co., Ltd.
- Warning letters
- 0
- State a violation of it
The regulation
The current text of 21 CFR 113.100 from the Electronic Code of Federal Regulations.
§ 113.100 Processing and production records.
(a) Processing and production information shall be entered at the time it is observed by the retort or processing system operator, or other designated person, on forms that include the product, the code number, the date, the retort or processing system number, the size of container, the approximate number of containers per coding interval, the initial temperature, the actual processing time, the temperature-indicating device and temperature-recording device readings, and other appropriate processing data. Closing machine vacuum in vacuum-packed products, maximum fill-in or drained weight, or other critical factors specified in the scheduled process shall also be recorded. In addition, the following records shall be maintained:
(1) Still retorts. Time steam on; time temperature up to processing temperature; time steam off; venting time and temperature to which vented.
(2) Agitating retorts. Functioning of condensate bleeder; retort speed; and, when specified in the scheduled process, headspace, consistency, maximum drained weight, minimum net weight, and percent solids.
(3) Hydrostatic retorts. The temperature in the steam chamber between the steam-water interface and the lowest container position; speed of the container conveyor chain; and, when the scheduled process specifies maintenance of particular temperatures in the hydrostatic water legs, the temperatures near the top and the bottom of each hydrostatic water leg.
(4) Aseptic processing and packaging systems. Product temperature in the holding tube outlet as indicated by the temperature-indicating device and the temperature-recording device; differential pressure as indicated by the differential pressure recorder-controller, if a product-to-product regenerator is used; product flow rate, as determined by the flow controlling device or by filling and closing rates; sterilization media flow rate or temperature or both; retention time of containers, and closures when applicable, in the sterilizing environment; and, when a batch system is used for container and/or closure sterilization, sterilization cycle times and temperatures.
(5) Flame sterilizers. Container conveyor speed; surface temperature at the beginning and at the end of the holding period; nature of container.
(6) Food preservation methods wherein critical factors such as water activity are used in conjunction with thermal processing. Product formulation and scheduled processes used, including the thermal process, its associated critical factors, as well as other critical factors, and results of aw determinations.
(7) Other systems. Critical factors specified in the formulation of the product or in the scheduled process.
(b) Temperature-recording device records shall be identified by date, retort number, and other data as necessary, so they can be correlated with the record of lots processed. Each entry on the processing and production records shall be made by the retort or processing system operator, or other designated person, at the time the specific retort or processing system condition or operation occurs, and this retort or processing system operator or other designated person shall sign or initial each record form. Not later than 1 working day after the actual process, and before shipment or release for distribution, a representative of plant management who is qualified by suitable training or experience shall review all processing and production records for completeness and to ensure that the product received the scheduled process. The records, including temperature-recording device records, shall be signed or initialed and dated by the reviewer.
(c) Records of the accuracy of a temperature-indicating device shall include:
(1) A reference to the tag, seal, or other means of identity used by the processor to identify the temperature-indicating device;
(2) The name of the manufacturer of the temperature-indicating device;
(3) The identity of the reference device, equipment, and procedures used for the accuracy test and to adjust the temperature-indicating device or, if an outside facility is used to conduct the accuracy test for the temperature-indicating device, a guarantee, certificate of accuracy, certificate of calibration, or other document from the facility that includes a statement or other documentation regarding the traceability of the accuracy to a National Institute of Standards and Technology (NIST) or other national metrology institute standard;
(4) The identity of the person or facility that performed the accuracy test and adjusted or calibrated the temperature-indicating device;
(5) The date and results of each accuracy test, including the amount of calibration adjustment; and
(6) The date on or before which the next accuracy test must be performed.
(d) Records of the accuracy of a reference device maintained by the processor shall include:
(1) A reference to the tag, seal, or other means of identity used by the processor to identify the reference device;
(2) The name of the manufacturer of the reference device;
(3) The identity of the equipment and reference to procedures used for the accuracy test and to adjust or calibrate the reference device or, if an outside facility is used to conduct the accuracy test for the reference device, a guarantee, certificate of accuracy, certificate of calibration, or other document from the facility that includes a statement or other documentation regarding the traceability of the accuracy to a NIST or other national metrology institute standard;
(4) The identity of the person or facility that performed the accuracy test and adjusted or calibrated the reference device;
(5) The date and results of each accuracy test, including the amount of calibration adjustment; and
(6) The date on or before which the next accuracy test must be performed.
(e) Records of all container closure examinations shall specify the product code, the date and time of container closure inspections, the measurements obtained, and all corrective actions taken. Records shall be signed or initialed by the container closure inspector and reviewed by management with sufficient frequency to ensure that the containers are hermetically sealed. The records shall be signed or initialed and dated by the reviewer.
(f) Records shall be maintained to identify the initial distribution of the finished product to facilitate, when necessary, the segregation of specific food lots that may have become contaminated or otherwise rendered unfit for their intended use.
(g) Copies of all records provided for in this part, except those required under § 113.83 establishing scheduled processes, shall be retained at the processing plant for a period of not less than 1 year from the date of manufacture, and at the processing plant or other reasonably accessible location for an additional 2 years. If, during the first year of the 3-year record-retention period, the processing plant is closed for a prolonged period between seasonal packs, the records may be transferred to some other reasonably accessible location at the end of the seasonal pack.
(h) Records of this part may be maintained electronically, provided they are in compliance with part 11 of this chapter.
21 CFR Part 113: Thermally Processed Low-Acid Foods Packaged in Hermetically Sealed Containers, Subpart FRead on eCFR
Citations by year
Form 483 citations of 21 CFR 113.100 by the year the inspection ended. FDA's citation data starts with inspections ending in October 2008, and the current year runs to the latest sync, so both are partial years (lighter bars).
Peak: 2 in 2023
| Year | Form 483 citations |
|---|---|
| 2023 | 2 |
| 2026 | 1 |
How FDA words this citation
FDA's short descriptions and citation text on these 3 citations, most used first. These are FDA's standard summaries in its citation data, not the text of any one Form 483.
Short descriptions
- Other systems - records; critical factors1 citations
- Recording device records - dated; retort number1 citations
- Review of processing and production records1 citations
Citation text
- “A processing and production record was not reviewed by a representative of plant management qualified by suitable training or experience to determine completeness of the record and whether the product received the scheduled process.”1 citations
- “Records were not maintained for critical factors specified in the scheduled process.”1 citations
- “Temperature-recording device records were not identified by data necessary to correlate the temperature-recording device with the record of lots processed.”1 citations
Facilities cited most recently
The latest inspections where FDA cited 21 CFR 113.100, by inspection end date, with FDA's short description. Each links to the facility's FDA record on FDAgent.
- Premier Canning Industry Co., Ltd.2026-09-03 · FEI 3004321705Other systems - records; critical factors
- Regal Kitchen Foods Limited2023-06-05 · FEI 3013516786Recording device records - dated; retort number
Often cited at the same inspection
Of the 3 inspections where FDA cited 21 CFR 113.100, the share where it also cited each of these sections.
- 21 CFR 507.34Preventive controls1 (33%)
Ask FDAgent about 21 CFR 113.100
FDAgent reads FDA's Form 483 citations, observations and warning letters and answers in plain English, with links to the records.
Related
About this data
- Citation counts come from FDA's Data Dashboard, which lists the regulation behind each Form 483 observation for inspections since October 2008.
- Observation excerpts come from Form 483 PDFs in FDA's electronic reading room, tied to this section only by exact wording as described above.
- A warning letter counts for this section when one of its numbered violation sentences cites 21 CFR 113.100; FDAgent quotes that sentence exactly.